B Deck Profile Roof Load Table Floor Load Table Concrete Load Table

Type B Roof Deck Load Table - Wide Flange Up

Uniform Total Load in Pounds Per Square Foot (Dead and Live)

Span

Ga

Design Thickness

5

5.5

6

6.5

7

7.5

8

8.5

9

9.5

10

1

22

.0295

96

75

60

49

41

35

31

 

 

 

 

20

.0358

120

93

74

60

50

43

37

32

 

 

 

18

.0474

166

127

100

81

67

56

48

42

37

33

 

16

.0600

 

158

124

100

82

68

58

50

44

39

35

2

22

.0295

103

86

72

62

53

46

41

36

32

 

 

20

.0358

127

105

88

75

65

57

50

44

40

36

32

18

.0474

169

140

118

101

87

76

67

59

53

48

43

16

.0600

 

177

149

127

110

96

84

75

67

60

54

3

22

.0295

128

107

90

77

66

58

50

43

38

34

30

20

.0358

157

130

110

94

81

71

61

53

46

40

36

18

.0474

 

174

147

125

108

95

82

70

60

53

47

16

.0600

 

 

185

158

137

119

101

86

74

64

57

NOTES:  1. Load tables are calculated using section properties based on the steel design

                thickness shown in the Steel Deck Institute (SDI) design manual.

 

             2. Loads shown in the shaded areas are governed by the live load deflection

                 not in excess of L/240 of the span.  A dead load of 10 psf has been included
 
Contact your design professional for proper use of Flexospan load tables

 


Flexospan Steel Buildings - Metal Roofing, Siding, Purlins, Girts, Self-Storage